Get Quotes

PRODUCT DETAILS

OES Spectrometer Metals Analyzer

Band nameICLEAR
Model No.CHL-M4
CertificateISO CE
Add to Favorites

Quick Details

Wavelength Range: 175-520nm
Spark Stand: Argon flushed and optimized Argon flow
Base: Fe, Al, Cu, Zn, Ni, Ti, Mg
Calibration: Freely selected analysis programs
Software: Microsoft Windows operating system
Room temperature: 10℃~30℃
Relative humidity: 20%~80%

Packaging & Delivery

Size: 818X590X396mm
Weight: 70KGS

Product Description

OES Spectrometer Metals Analyzer 

CHL-M4
Overview
M4 Metals Analyzer creatively combined with world leading argon circulation technology enables the analysis of Fe, Al, Cu and other bases materials. It is an ideal solution to fast and accurate quantitative analysis near the furnace, metal material quality control and scientific research.
 
Applications
Metallurgy, Foundry, Metal processing, Metal materials quality identification, Application of new alloys.
 
Features
Argon Circulation
•Excellent sealing of optics keeps long time internal argon purity.
•Advanced argon purged optics, optimized performance for UV elements.
•Argoncirculation filter device eliminates the air molecules and improves the reliability of optics.
•Stable pressure of optics avoids the optical drift and enhances long-term stability of the instrument.
•Low argon consumption and economic efficiency.

CCD full spectrum analysis technology
•Abundant spectrums, better accuracy of the analysis.
•Full spectrum distinguishing background to improve analysis accuracy. 
•Intelligently selecting appropriate sensitive wavelength, applied multi-spectrum fitting technology, outstanding performance for general value of content.
•Application of multi-spectrum fitting technology eliminates the interference of the spectrum and achieves accurate measurement.
 
Smart and reliable digital source
Programmable digitalized spark source, suitable for different bases improving the analysis accuracy.
 
Easily operated sample clamp
Open spark stand with smaller internal space reduces the gas consumption.
Four-way argon flushing design effectively removes residual dust, less maintenance.
 
Advanced and stable optical system
Paschen-Runge optical system with full wavelength coverage, Multi-CCD detectors with high resolution.
Real-time monitoring and constant temperatureguaranteesthe stability of the optical system.
 
Customized sample clamp
Customized sample clamp adapted to different sample geometrics.
 
One-button operation
One-button operation for quick and easy handling, adjusted to factory requirement.
 
Original real-time intelligent drift correction technology
Real time spectrum drift correction when analyzing, enhances the stability of instrument.
Reduce frequency of standardization.
Automatic calibration, easier operation.
 
Professional and simplified operating software
•Intelligent Program
Intelligently select the matching program to obtain more accurate analysis results
Enable Quantitative analysis of unknown samples.
 
•Quality Control
Easily set the upper and lower limits according to user's quality standards.
Automatically determine whether sample composition pass or fail.
 
•Grade Identification
 Identify sample grade fast and easily classify unknown materials.
 
•Equivalent Analysis.
Editable carbon equivalent and corrosion resistance  equivalent equation, better control to the quality of alloy.
 
•Automatic Diagnosis System
Software interface indicating real time instrument running status.
Warning the instrument maintenance and cleaning time.

Technical Specifications
Argon Circulation
•Excellent sealing of optics keeps long time internal argon purity.
•Advanced argon purged optics, optimized performance for UV elements.
•Argoncirculation filter device eliminates the air molecules and improves the reliability of optics.
•Stable pressure of optics avoids the optical drift and enhances long-term stability of the instrument.
•Low argon consumption and economic efficiency.
 
CCD full spectrum analysis technology
•Abundant spectrums, better accuracy of the analysis.
•Full spectrum distinguishing background to improve analysis accuracy. 
•Intelligently selecting appropriate sensitive wavelength, applied multi-spectrum fitting technology, outstanding performance for general value of content.
•Application of multi-spectrum fitting technology eliminates the interference of the spectrum and achieves accurate measurement.
 
Smart and reliable digital source
Programmable digitalized spark source, suitable for different bases improving the analysis accuracy.
 
Easily operated sample clamp
Open spark stand with smaller internal space reduces the gas consumption.
Four-way argon flushing design effectively removes residual dust, less maintenance.
 
Advanced and stable optical system
Paschen-Runge optical system with full wavelength coverage, Multi-CCD detectors with high resolution.
Real-time monitoring and constant temperatureguaranteesthe stability of the optical system.
 
Customized sample clamp
Customized sample clamp adapted to different sample geometrics.
 
One-button operation
One-button operation for quick and easy handling, adjusted to factory requirement
 
Original real-time intelligent drift correction technology
Real time spectrum drift correction when analyzing, enhances the stability of instrument.
Reduce frequency of standardization.
Automatic calibration, easier operation.

Professional and simplified operating software
•Intelligent Program
Intelligently select the matching program to obtain more accurate analysis results
Enable Quantitative analysis of unknown samples.
 
•Quality Control
Easily set the upper and lower limits according to user's quality standards.
Automatically determine whether sample composition pass or fail.
 
•Grade Identification
 Identify sample grade fast and easily classify unknown materials.
 
•Equivalent Analysis.
Editable carbon equivalent and corrosion resistance  equivalent equation, better control to the quality of alloy.
 
•Automatic Diagnosis System
Software interface indicating real time instrument running status.
Warning the instrument maintenance and cleaning time.

Models
Model Wavelength Description
M4 N 175-520   nm Available   for bases such as Fe, Al, Cu
M4 S 200-520   nm Available   for bases of Al, Cu