Total Organic Carbon TOC Analyzer

Band nameICLEAR
Model No.CHL-TOC2000/3000
CertificateISO CE
Add to Favorites

Quick Details

Operation Mode: PC Control
Application: Liquid Sample, Gas Sample, Solid Sample
Gas Requirement: Oxygen, Nitrogen≥99.995%
Measurement Range: 0-30000mg/l
Detection Limit: 50μg/l
Repeatability: 3%
Maximum Salinity: 85g/l

Packaging & Delivery

Product Description

Total Organic Carbon TOC Analyzer 

CHL-TOC2000/3000

Features

1. Signal management system with our own patent law which has great advantages of online setting, real-time monitoring, self testing and flow speed control to ensure high performance and safe operation.

2.  Low current system design also ensures operation safety.

3.  Different temperature setting for various samples ensures complete sample digestion so as to get more accurate measuring data.

4.  Adjust cooling module power according to sampling volume which improves drying performance to ensure dry gas into the detector.

5.  Automatic leak check system to avoid operation mistakes and improve instrument performance, so as to ensure operation safety and instrument’s safety

7.  TOC detector with 24 bits data solution extends monitoring range. Controlling system with 32bin processing technology greatly improves performance.

Specifications

 Model

TOC-2000

 Detector

NDIR

Parameters

TC, TIC, TOC

 Digestion Mode

High Temperature Combustion

 Operation Mode

PC Control

 Application

Liquid Sample, Gas Sample, Solid Sample

 Gas Requirement

Oxygen, Nitrogen≥99.995%

Measurement Range       

0-30000mg/l

Detection Limit

50μg/l

 Repeatability

 3%

Maximum Salinity

 85g/l

Power 

220±10V,50/60HZ, 1KW

Size

 430*455*440mm


Specifications

 Model

TOC-3000

 Detector

NDIR

Parameters

TC, TIC, TOC

 Digestion Mode

Wet chemical oxidation by UV

 Operation Mode

PC Control

 Application

Liquid Sample, Gas Sample

 Gas Requirement

Oxygen, Nitrogen≥99.995%

Measurement Range       

0-10000mg/l

Detection Limit

50μg/l

 Repeatability

 3%

Maximum Salinity

 85g/l

Power 

220±10V,50/60HZ, 1KW

Size

 430*455*440mm

 