Testing Method Low pressure ion exchange liquid chromatography
Testing Item Glycated hemoglobin HbA1c
Testing Scope 3%-18%
Testing Parameters Precision(CV)≤3% Accuracy(V) ≤1.50%
Testing Time 4 minutes(reporting) Full-processing 6 minutes(including cleaning column and recovery time)
Sample Type Venous blood(EDTA anticoagulation) Peripheral finger blood
Sample Volume 5ul Whole blood for each sample
Full-auto Glycated Hemoglobin HbA1c Analyzer
CHL-H760
Testing Method |
Low pressure ion exchange liquid chromatography |
Testing Item |
Glycated hemoglobin HbA1c |
Testing Scope |
3%-18% |
Testing Parameters |
Precision(CV)≤3%, Accuracy(V) ≤1.50% |
Testing Time |
4 minutes(reporting), Full-processing 6 minutes(including cleaning column and recovery time) |
Sample Type |
Venous blood(EDTA anticoagulation), Peripheral finger blood |
Sample Volume |
5ul Whole blood for each sample |
Functional Parameters |
Photometer |
415nm LED Integral flow colorimeter |
Sampling mode |
Fully-auto 20 position sample turntable |
Testing mode |
Auto test for batch, single test for emergency |
Calibration |
Optional selection of 2 points or 4 points calibration, optional selection of manual or automation, Equipped with 2 groups of high and low level calibrators |
Thermostatic control |
Column and reagent thermostatic control: 25 ±0.5℃ |
Reagent matching |
One piece of column and reagent consumable/300 pieces of testing samples |
Reagent allocation |
Each standard package inclues A, B, C, D eluent, calibrator, hemolytic agent, pump tubing |
Output Parameters |
Display |
320×240 LC Graphic display, displaying real-time testing curve |
Printer |
58nm Thermal printer, printing testing curve and report |
Report Output |
IFCC concentration value, NGSP area percentage, ADAG average glucose |
Data storage |
1000test report(including testing curve) |
Communication interface |
RS232 communication interface, connecting to HIS/LIS system |
Working Parameters |
Power Supply |
AC220V±22V, 50HZ, 65VA |
Size |
408*390*230mm |
Weight |
8KG |
Working Environment |
Temperature 12-30℃, Relative humidity ≤85% |
●Accurate Principle of Methodology
Adopts classical and accurate principle of methodology – Ion exchange liquid chromatography, It is the gold standard of HbA1C analysis, and it is the only analysis method to really separate HbA1C directly by measuring the piecemeal absorbance through continuous test on line,? and obtain the correct area percentage with integration.
●Accurate separation 4-gradient elution
The novel 4-gradient elution for HbA1C can separate accurately glycated hemoglobin with 4-gradient elution of corresponding concentration reagent aiming at HbA1C instead of routine ?elution process produced by high and low concentration mixture.
●High Separation Liquid Chromatographic Column
High separation liquid chromatographic column made of imported resin with volume of Φ 9mm x 45mm and weight of 2.5g which is 15 – 20 times greater than general micro chromatographic column. High efficiency chromatographic column for 300 tests ensure the accuracy of test results.
●High Sensitivity 415nm LED Integral Photometer
High sensitivity 415nm LED integral photometer has the characteristics of correct wavelength, stable light source, full aluminum alloy structure, high anti-interference performance, multi-lens focusing, micro cuvettes and high sensitivity. It can record accurately analysis curve.
●Supply with Original Calibrator
The international standard value tracing is adopted. The authoritative reference material for quality control is used to transfer the numeric value. Each set of reagent is supplied with two sets of calibrator for proper calibration so as to ensure that the test results are correct and reliable and thoroughly to avoid individual error caused by factor calibration.
●Precision Chromatographic Column and Thermostatic Apparatus
Precision chromatographic column and reagent thermostatic control apparatus ensure that Chromatographic column and reagent are not affected by environment temperature and effectively guarantees the repeatability and correctness of the test results