Get Quotes

Product Categories

Anti-Virus

VET

Endoscope System

Ultrasounds

X Ray

In Vitro Diagnosis

General Lab Device

Analytical Instruments

Medical Training Models

ENT

Ear products

Ophthalmology

Dental Products

Monitor/Examiner

Emergency Products

Anaesthesia/Ventilator

Surgical Equipment

Male/Female/Kids

Physical Therapy

Hospital Furniture

PRODUCT DETAILS

Veterinary Equipment Automatic Ovulation Tester Pig Cow Dog Ovulation Tester Pig Sheep Cattle Estrus Tester

Band nameICLEAR
Model No.CHV-OT1
CertificateNone
Add to Favorites

Quick Details

Product parameters
Test method: fully automatic one test
Test speed: within 3 seconds
Net weight: about 300 grams
Electricity: One 9-volt battery, model 6F22
Display: LCD screen, about 2.6 inches
Measuring range: 10-1990
Maximum humidity: 85%
Working temperature: 0-50°c
Basic configuration: one instrument, one manual, one certificate of conformity, one warranty card
Measurement methods.

Packaging & Delivery

1.5kg

Product Description

Veterinary Equipment Automatic Ovulation Tester Pig Cow Dog Ovulation Tester Pig Sheep Cattle Estrus Tester 

CHV-OT1


Product parameters
Test method: fully automatic one test
Test speed: within 3 seconds
Net weight: about 300 grams
Electricity: One 9-volt battery, model 6F22
Display: LCD screen, about 2.6 inches
Measuring range: 10-1990
Maximum humidity: 85%
Working temperature: 0-50°c
Basic configuration: one instrument, one manual, one certificate of conformity, one warranty card
Measurement methods.

A. Operation method
1) The detergent must be poured on the cotton cloth, the probe of the instrument must be wiped repeatedly, rinsed with clean water, used directly, and do not dry again (use a wet towel or toilet paper to clean up the feces, hair or other dirt sticking to the vulva of the ewe) .
2) Separate the vulva of the ewe by hand, insert the instrument at a 45-degree angle and gently insert it upwards, leaving the white probe outside about 2CM. All others are inserted. The instrument is then rotated one and a half to two weeks to allow the mucus to fully contact the probe.
3) Keep the sheep standing normally at this moment, turn on the switch, wait for a set of data to appear on the display, click the switch again, wait for the second set of numbers to appear on the display, then press the third button, and the third set of data appears on the display data.
4) After the operation, if you test again, it must be tested again for at least 2-3 hours. Because there is a recovery period after the mucus is stirred, a second test cannot be performed immediately.
5) Keep the instrument clean and put away.
B. Data Judgment
Sheep:The data is above 600 when not in heat
After estrus, the data will drop to below 200, and then the breeding time will be carried out when it rises to above 550.
C. Precautions
1) Take three sets of data just to ensure the correctness of the operation and judge according to this data. For example, the three sets of data are 310, 280, and 270 respectively. We can directly judge according to the last two sets of data. These three sets of data are not averaged. If the test data is divided into 240, 360, and 540, it means that there is a problem with the operation and needs to be re-measured. The interval between re-measurement must be at least 2 to 3 hours. . Because the test has messed up the resistance value of the mucus, a short recovery period is required.
2) It is recommended that you do not transfer the analyzer to reduce the risk of transmission of infectious diseases. Strictly follow disinfection procedures.
Store the analyzer dry at room temperature. Do not use hot or boiling water for cleaning.
Dirt, sebum oil, urine, saline solution on the electrodes can lead to false results. Read the data at the cervix, and ensure the same position for each test.

Related Products