PRODUCT DETAILS
Best price 10 Channels C13 Urea Breath Test Helicobacter Pylori HP Detector
Band nameICLEAR
Model No.CHL-HPC13
CertificateISO
Add to Favorites
Quick Details
High efficiency
Fast operation, 2-3 minutes for one set samples
automatic batch testing 10channels, automatic beach testing
Simple
One-touch operation, automatic control system
Accurate
Good repeatability, standard error <0.2%
Packaging & Delivery
Dimension: 540 mm×404 mm×345 mm;
Weight: 18kgs;
Product Description
Best price 10 Channels C13 Urea Breath Test Helicobacter Pylori HP Detector
CHL-HPC13
Scope of application:
This product is used in conjunction with the gastric Helicobacter pylori detection kit and is used in clinical institutions to detect gastric Helicobacter pylori in vitro through the 13C urea breath test.
Measuring principle:
Urease produced by Helicobacter pylori (Hp) in the human stomach can decompose urea [13C] reagent into NH3 and 13CO2. This instrument uses non-divergent red
The principle of external absorption spectroscopy measures the change in the ratio of the content of 13CO2 and 12CO2 in the exhaled air before and after the subject takes the urea [13C] reagent.
In order to determine whether the subject is infected with Hp in the stomach.
High efficiency
Fast operation, 2-3 minutes for one set samples
automatic batch testing 10channels, automatic beach testing
Simple
One-touch operation, automatic control system
Accurate
Good repeatability, standard error <0.2%
Specifications:
1. The self-developed infrared light source has a temperature of 950ºC, high efficiency, long life, and low attenuation.
2. Highly sensitive imported infrared sensor, the detector adopts imported PbSe infrared photosensitive detection element, which is stable and reliable.
3. Sampling system: sampling system with micro solenoid valve and imported brushless motor micro pump.
4. 10-channel equipment to improve detection efficiency.
5. Start-up preheating time is ≤20 minutes, the detection sample concentration range is 1%-6%, and the analysis speed is ≤2.5 minutes/pair of samples.
6. One-click software operation, good user experience, the software interface is all in Chinese, easy to query patient information, and store patient information.
7. No need for standard gas calibration, easy to maintain.
8. The print template can be customized and modified, and the data backup and recovery capabilities are strong.
9. Long data storage time, real-time statistics of historical data, past positive data, and repetition rate.
10. Small size, lightweight, easy to store, change location, size 320±10x565±20x225±10 (mm) weight 15±1Kg.
C -Urea Breath Test kit
Applicable for all ages and types of subjects, including pregnant women and young children
Product Highlights:
Sensitivity 95% Specificity100%;
Painless & Non-invasive, well accepted by patients,
Analysis result generated within 5 mins;
Applicable for any age;