China Hospitcal Double Pumps Blood Hemodialysis Kidney Dialysis Machine

Band nameICLEAR
Model No.CHH-H28
CertificateCE ISO
Add to Favorites

Quick Details

· Double pumps: blood pump and spare pump providing more treatment options; Compatible with bloodlines of different diameters.
· Single & Double-needle dialysis.
· Using magnetic valves made in Switzerland.

Packaging & Delivery

100X50X50 cm weight: 180.0 kg

Product Description

China Hospitcal Double Pumps Blood Hemodialysis Kidney Dialysis Machine 
CHH-H28


Features
· LCD touch screen with high definition(10.4").
· Automation: Self-test, rinse, disinfection, hot disinfection, ISO UF, shutdown, etc. Automatically start treatment once blood flow is sensed.
· Bicarbonate dry powder cartridge.
· Use with dialysis fluid of various formulas (acetate & bicarbonate).
· Kt/V function.
· Double pumps: blood pump and spare pump providing more treatment options; Compatible with bloodlines of different diameters.
· Single & Double-needle dialysis.
· Using magnetic valves made in Switzerland.
· In-built battery backup for max. 30 minutes.
· Dialyzate flux linearity adjustable (300~800mL/min).
· Support bedside treatment. 
· HCO3 adjustment for serious acid toxicosis patient.


Audible & visible alarm with warning messages & troubleshooting.
· Blood flow monitoring.
· Arterial and Venous pressure monitoring.
· Transmembrane pressure(TMP) monitoring.
· Noninvasive blood pressure(NIBP) monitoring.
· Air Monitoring: Air bubble detector using infrared sensor; Blood level detector using ultrasonic sensor.
· Blood leak monitoring.
· Waterway entirely apart from the electric way.
· Dialyzate temperature is selectable between 35 and 39 ºC.
· Conductivity is controllable.
· Sodium and ultrafiltration profiles for various treatment conditions.
· Heparin pump timing for safety and convenience.
· Disinfection: Rinsing, hot disinfection, chemical disinfection; Double-circulation disinfection system: Fluid supply loop and return loop are completely separated during disinfection to avoid pollution of the whole machine in case of mis-sucking disinfection liquid. This gives protection from intercross infection.


Specifications

General Data · Dimensions: 370x340x1420mm (LxWxH)
· Weight: 90 Kg
· Water inlet pressure: 0~0.6MPa
· Water inlet temperature: 5~30ºC
· Ambient temperature: 10~30ºC
· Relative Humidity ≤70%
Extracorporeal Circuit · Arterial pressure monitoring:
Display range: -300~+300mmHg (±10mmHg)
· Venous pressure monitoring:
Display range: -50~+300mmHg (±10mmHg)
· TMP range: -100~+600mmHg (±20mmHg)
Arterial pressure monitoring: Display range: -300~+300mmHg (±10mmHg)
Venous pressure monitoring: Display range: -50~+300mmHg (±10mmHg)
TMP range:  -100~+600mmHg (±20mmHg)
Blood pump/ Spare pump: Flow range: 15~340mL/min (φ 6mm)   20~620mL/min (φ 8mm)
Blood level detector:    ultrasonic sensor.
Air bubble detector:  infrared sensor.
Threshold of reaction:  single air bubble of 200 μI exists when blood flux is 200mL/min
Heparin pump: Delivery range: 0.1~10mL/hr (±5%)     
Accuracy: 0.1mL/hr Injector size: 10/20/30mL,   20/30/50mL (optional)
Electrical Data · Power: 1500W                 
· Frequency:   50/60Hz
· Voltage: AC220V±10% (110V optional)
Dialysis Fluid Circuit · Dialysate flow range: linearity adjustable 300~800mL/min
· Dialysate temperature range: Selectable 35~39ºC
· Dialysate conductivity range: 13~15.5mS/cm (±0.1mS/cm)
· UF flow range: 0~4000mL/hr (±30mL/hr)
· ISO UF flow range: 0~2000mL/hr (±30mL/hr)
Blood leak detector:  Automatically close the blood loop when blood leak ≥1mL per liter dialysate 
(Flow: 500mL/min)
Disinfection and Cleaning · Disinfection: Use citric acid, peracetic acid, and sodium hypochlorite.
· Hot rinse temperature: 90ºC
 