Steam Validation Sterilization Indicator Tape Bowie Dick Pack

Band nameICLEAR
Model No.CHL-SIB Series
CertificateISO CE
Add to Favorites

Quick Details

Product size 115*125mm
Shape: square
Sterilization method: pressure steam sterilization
Custom processing available

Packaging & Delivery

200pcs/box

Product Description

Steam Validation Sterilization Indicator Tape Bowie Dick Pack


CHL-SIB Series

Product size 115*125mm
Shape: square
Sterilization method: pressure steam sterilization
Custom processing available
Medical disinfection BD test kit Description:
The BD test consists of a B-D test paper, a laminate, a laminated laminate, a foam sheet, and a wrinkled paper on the outer bread and packaged by a piece of indicator label. The BD test paper is printed with a vapor-sensitive indicator ink placed close to the center of the laminate material. During the sterilization process, the vapor can penetrate the laminate with good permeability to react with the indicator ink on the BD test paper, making the BD test paper Change from yellow to black. The pattern on the BD test paper, under normal circumstances, the sterilizer runs at 132 ° C or 134 ° C for 3.5 minutes, the pattern will become uniform dark brown to black; if the cold air is not completely removed, the cold air inside the package The penetration of the steam will be affected, so that the center of the BD test paper is formed differently from the surrounding light color area, thereby reflecting the sterilizer's effect of eliminating cold air. The indicator label on the outside of the test kit is also printed with a vapor-sensitive indicator ink that changes from yellow to black after steam sterilization, indicating that the test kit has been used.
 
Application range:
The medical BD test kit is suitable for the detection of the air removal effect of the pre-vacuum pressure steam sterilizer. It can be used for the monitoring of the air removal effect in daily sterilization, the verification when designing the sterilization operation procedure, the performance determination in the sterilizer development, and the new extinction. The measurement of the effect after the installation and commissioning of the fungus, and the measurement of the performance after the maintenance of the sterilizer.
 
Usage:
1. The sterilizer is preheated to the appropriate temperature.
2. In the case of an empty pot, place the BD test bag above the exhaust port, near the door, with the label side up and flat.
3. Run the sterilizer for 3.5 minutes (132 ° C or 134 ° C). Any overtime work will affect the B-D test results. If the operation exceeds 4 minutes, the sensitivity of the test paper will decrease and the result of false negative will be observed.
4. After the end of the cycle, check the BD test paper.