Get Quotes

PRODUCT DETAILS

Atomic Absorption Spectrophotometer AAS with Double-beam System Optional Agraphite Furnace & Hydride Generator

Band nameICLEAR
Model No.CHL-AA320N
CertificateIOS CE FDA
Add to Favorites

Quick Details

Double beam all reflective optical system
Deuterium lamp backdrop
Single lamp holder, manual regulation of gas flow
Acetylene air combustion method
Graphite furnace method (selection)
Hydride generation method(selection)

Packaging & Delivery

Packing Size(mm): 1250*800*750 (Main instrument)/550*460*1350  ( Accessories )
Gross Weight(kg): 150Kg  (Main instrument)/50Kg   ( Accessories )

Product Description

Atomic Absorption Spectrophotometer AAS with Double-beam System
Optional Agraphite Furnace & Hydride Generator


CHL-AA320N 

COMMON FEATURES 

  1. Build-in computer data processing and LCD display: stable and reliable with the functions of integral holding, peak height and area, auto zero adjusting, deuterium lamp background correction, multi-linear and nonlinear curves fitting, various parameters and working curves displayed in screen and report printing, etc. It is equipped with interface for externally linking PC.
  2. Stability: Double-beam system can automatically compensate the light source drift and wavelength drift caused by the variation of temperature (with the function of the eliminating the affection of wavelength drift on the base line stability) and electronic circuit drift so as to reach a good basic line stability.
  3. Quickly:The cathode lamp needs not be pre-heated for long time and sample can be analyzed immediately. It is the preferable instrument chosen by users to conduct analysis of multiple kinds of elements and fast analysis of samples.
  4. High precision of measurement:Gas path system is equipped with precision pressure stabilizing and current stabilizing devices to reach stable flame and low noise. Specially designed fine light beam passes through the flame to ensure a high precision analytical test and low characteristic concentration
  5. High energy optical path: A total reflection system is adopted to eliminate color difference in full range. By means of chemical conversion, a round light spot of the light source becomes a long light spot, which enters into the slit. There- fore the light flux of double beam is enhanced. 
  6. Long-life and anti-corrosive atomization system: The burner is made of new type titanium alloys, anti-corrosive and fast thermal equilibrium. It meets the requirement of measurement sensitivity without water-cooling. 
  7. Multi-functionalanalysismode:formethodsofflameabsorption,flameemission,graphitefurnaceatomicabsorption and hydride generation.
  8. Safe and reliable gas path system: Special devices of quick gas conversion and safety protection can be used to analyze air-acetylene flame as well as nitrous oxide-acetylene flame and extend the analytic elements to reach more than 0.
  9. Complete set of accessories: to be supplied with the instrument and ready for use after they are purchased.

STANDARD ACCESSORIES
Oil-free air compressor Glass Atomizer
Cu Hollow cathode lamp Atomizer unit
Burner unit
Dust cover Water-separating gas filter Titanium burner---10cm 

OPTIONAL ACCESSORIES
Model GA3202 HGA graphite furnace system Hydride generator
Graphite tubes
Acetylene Regulator YQE-213
Software
Recirculating cooling water system 
 

Features


Model

CHL-AA320N

Wavelength Range

190~900nm 

Wavelength Accuracy

±0.5nm

Wavelength Repeatability

≤ 0.3nm (single direction)

Spectral Bandwidth

0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm

Resolution

<40%

Base Line Stability

±0.004Abs/30min

Characteristic Concentration 

≤ 0.04μg/ml/1% (Cu)

Detection Limit

≤0.008μg/ml (Cu)

Background Calibration

 >30 times

Power Supply

220V, 50/60Hz

Packing Size(mm)

1250*800*750 (Main instrument)

 550*460*1350  ( Accessories )

Gross Weight(kg)

150Kg  (Main instrument)

50Kg   ( Accessories )

Standard Accessories

RS232 serial port

Oil-free air compressor

Glass Atomizer

Cu Hollow cathode lamp

Atomizer unit, Burner unit ,Dust cover

Water-separating gas filter

Titanium burner---10cm

Optional Accessories

Printer

Model GA3202 HGA graphite furnace system

Hydride generator

Graphite tubes

Software

Recirculating cooling water system

Hollow cathode lamp(Ag, Au, Ba, Ca, Cd, Cr ,Fe, Hg ,K, Li, Mg,Mn, Na, Ni, Pb, Zn, Sb,etc)




Related Products